FLX ASI DI 4 M12
I1
I2
Fieldline Extension AS-i M12 device
with four digital inputs
I3
I4
PW
R
FA
UL
T
FL
OrdX AS
er- I D
No I 4
.: 2 M
7 7 12
34
29
co
© PHOENIX CONTACT - 01/2009
Description
Features
ne
po
om
–
–
in
ec
–
–
–
on
l
–
–
Four digital inputs
AS-i connection via flat-ribbon cable
(penetration technique)
No tools required for connection to the flat-ribbon cable
Connection of digital sensors using M12 connectors
(SPEEDCON fast connection technology)
AS-i voltage indication
Diagnostic and status indicators
Short-circuit and overload protection
of the sensor supply
AB slave
IP65/IP67 degree of protection
nt
s.
The device is designed for use within an AS-Interface
system. It is used to acquire digital signals.
–
–
m
Data sheet
7465_en_01
1
AD
DR
AUTOMATION
Make sure you always use the latest documentation.
It can be downloaded at www.phoenixcontact.net/download.
FLX ASI DI 4 M12
2
Ordering data
Type
Order No.
Pcs./Pkt.
Fieldline Extension AS-i M12 device with four digital inputs
FLX ASI DI 4 M12
2773429
1
Accessories
Description
Type
Order No.
Pcs./Pkt.
Protective caps (for unused female connectors)
PROT-M12
1680539
5
Manual addressing device for AS-Interface devices
ASI CC ADR
2741338
1
Programming cable for connecting AS-Interface devices to the manual
addressing device
ASI CC ADR CAB CINCH
2741341
1
m
Device
Description
Documentation
Description
s.
co
Additional accessories for connecting the sensors can be found in the Phoenix Contact PLUSCON catalog.
Pcs./Pkt.
UM EN FLX ASI SYS PRO INST
–
–
User Manual: AS-Interface addressing device
ASI CC ADR UM E
9013727
1
ne
Technical data
58
om
108
in
ec
29
46
34.5
155
po
3
Type
nt
Order No.
User Manual: Configuring and installing of devices
in the Fieldline Extension AS-Interface product group
118
Dimensions of the device in mm
on
l
Figure 1
7465B002
General data
Dimensions (width x height x depth); including mounting base
58 mm x 118 mm x 34.5 mm
Weight
195 g
Connection method for sensors
2, 3, and 4-wire technology
Permissible temperature (operation)
-25°C to +70°C
Permissible temperature (storage/transport)
-25°C to +85°C
Degree of protection
IP65/IP67 according to IEC 60529
Protection class
Class 3 according to IEC 61140
7465_en_01
PHOENIX CONTACT
2
FLX ASI DI 4 M12
Mechanical requirements
Vibration test, sinusoidal vibrations according to EN 60068-2-6
5 g load in each space direction
Shock test according to EN 60068-2-27
30 g load, half sinusoidal wave positive and negative in each space direction
For additional information on mechanical requirements and ambient conditions, please contact Phoenix Contact.
Power supply
Communications power and sensor supply voltage ULS
26.5 V to 31.6 V from AS-Interface
≤ 40 mA + sensor current (200 mA, maximum)
Surge protection
ULS: Surge Voltage Category III
m
Current consumption at ULS
Digital inputs
4
Input design
According to IEC 61131-2 Type 2
co
Number
Maximum low-level voltage
ULmax < 5 V
Minimum high-level voltage
UHmin > 11 V
30 V DC from AS-i
nt
Nominal input voltage
s.
Definition of switching thresholds
-3 V DC < UIN < +30 V DC
8 mA
Current flow
Non-linear < 10 mA
ne
Range
Nominal input current
Delay time
tON < 1 ms, typical
tOFF < 1 ms, typical
< 30 m
0
1
2
in
ec
3
om
Input characteristic curve
Input voltage (V)
Typical input current (mA)
0
0.5
1.1
1.7
4
2.3
5
3.0
6
3.6
7
4.3
8
5.1
on
l
7465_en_01
po
Permissible cable length to the sensor
9
6.1
10
7.0
11
7.9
12
8.0
15
8.0
18
8.1
21
8.1
24
8.2
27
8.2
30
8.3
PHOENIX CONTACT
3
FLX ASI DI 4 M12
Sensor supply
Minimum sensor voltage
ULS – 7 V
Nominal current per channel
200 mA
Nominal current per device
200 mA
Connections
AS-Interface
Flat-ribbon cable penetration technique
Inputs
M12 female connector
Electrical isolation/isolation of the voltage ranges
Separate potentials in the FLX ASI DI 4 M12 device
Test distance
m
Test voltage
500 V AC, 50 Hz, 1 min.
co
30 V supply (sensor supply and communications power and inputs)/
housing
Approvals
4.1
AS-i connection
nt
Pin assignment
ne
4
s.
For the latest approvals, please visit www.phoenixcontact.net/download or www.phoenixcontact.net/catalog.
Designation
IN1 to IN4
AS-i
Meaning
Inputs 1 to 4
Connection to AS-i
(bus and power supply)
IN3
AS-i
on
l
IN1
in
ec
om
po
A connection to the AS-Interface is established by inserting
the AS-i flat-ribbon cable in the cable routing aid provided in
the mounting base of the device, and then making contact
with the module electronics. Contact is established as soon
as the locking latch snaps in.
IN2
IN4
AS-i
7465B003
Figure 2
7465_en_01
Connections of the FLX ASI DI 4 M12 device
PHOENIX CONTACT
4
FLX ASI DI 4 M12
4.2
Pin assignment of the inputs
Pin
1
2
3
4
5
6 6 2 5 A 0 0 6
Figure 3
Female input connectors
IN2
IN3
IN4
Sensor supply +
Not used
IN4
Not used
Sensor supply IN2
IN3
IN4
Not used
IN1
IN2
IN1
Pin assignment of the inputs
s.
Local diagnostic and status
indicators
nt
5
co
m
The M12 connectors are designed for a tightening
torque of 0.4 Nm.
I3
I4
Figure 4
7465_en_01
in
ec
on
l
PWR
FLT
po
I2
om
I1
ne
Designation
I1 to I4
PWR
FLT
Color
Yellow
ON
OFF
Green
Flashing
green
Red
Flashing
red
Meaning
Status indicators of the inputs
Input active
Input not active
AS-i supply voltage
Address 0
Communication failure
Sensor overload
7465B004
Local diagnostic and status indicators of the
FLX ASI DI 4 M12 device
PHOENIX CONTACT
5
FLX ASI DI 4 M12
6
Internal basic circuit diagram
Key:
LED
Input
Overload protection
Filter
Optocoupler
4
Protocol chip
ne
nt
A S I 4 U
s.
O v e r lo a d
P r o te c tio n
co
4
m
O v e r lo a d
P r o te c tio n
om
po
A S I 4 U
Internal wiring of the connections
on
l
Figure 5
in
ec
7 4 6 5 A 0 0 5
7465_en_01
PHOENIX CONTACT
6
FLX ASI DI 4 M12
Connection examples
IN 2
IN + 1
IN -1
IN 1
IN -2
IN 2
IN 1
IN + 2
7
Typical connection of sensors in 3-wire technology
s.
co
Figure 6
m
7 4 6 5 A 0 0 6
IN 2
ne
po
IN + 1
IN -1
Typical connection of sensors in 4-wire technology
Connection notes
in
ec
8
7 4 6 5 A 0 0 7
om
Figure 7
IN 1
IN 2
nt
IN 1
on
l
NOTE:
When using 4-wire sensors, opposite slots must
not be used.
NOTE: Avoid compensating currents
Each individual sensor must be insulated.
NOTE: Ensure degree of protection
NOTE:
To ensure IP65/IP67 protection, cover unused
female connectors with protective caps.
NOTE: Avoid damage to the electronics
Fix the device to a level surface or to a profile.
Do not use the device to bridge gaps, in order to
prevent forces from being transmitted via the
device.
An external power supply unit must never be used
to supply the sensors.
NOTE:
Tighten the mounting screws to a maximum of
2.8 Nm.
7465_en_01
PHOENIX CONTACT
7
FLX ASI DI 4 M12
9
Programming data
9.1
Configuration data
IO code
0hex
ID code
Ahex (extended addressing)
ID1 code
7hex (can be defined by the user)
ID2 code
2hex
Profile
S-0.A.2.
AS-i specification
2.1 (AB slave)
Bit
D0 IN
Input IN1
D0 OUT Not used
D1 IN
Input IN2
D1 OUT Not used
D2 IN
Input IN3
D2 OUT Not used
D3 IN
Input IN4
D3 OUT Not used
Function
P0
Not used
P1
Filter for the inputs in the AS-i IC
P1 = 0: Activated
P1 = 1: Deactivated
P2
Synchronous mode
P2 = 0: Activated
P2 = 1: Deactivated
P3
Not used
on
l
in
ec
om
Bit
ne
Parameter bit (programmable via AS-Interface)
po
9.3
Function
co
Function
s.
Bit
m
Data bit (function via AS-Interface)
nt
9.2
7465_en_01
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00
PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +1 (0) 717-944-1300
www.phoenixcontact.com
8